Source-audio Soundblox Pro Multiwave Distortion Pro Manuel d'utilisateur Page 11

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 13
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 10
Backpage Parameters | 2120 | Use with Hot Hand
BACKPAGE PARAMETERS
The MWD Pro has some additional controls that can only be editing
in a special mode called Backpage mode. Backpage mode is enabled
by pressing the
HH ENABLE and CALIBRATE buttons simultaneously, as
indicated on the main control panel. Backpage mode can be exited by
pressing the two buttons simultaneously again.
In Backpage mode, the
EQ controls and the Effect knob take on different
functions and the displays will change to indicate the parameter values.
For the
EQ display, there are two letter abbreviations above some of the
columns that indicate the parameter controlled in Backpage mode. Select
the parameter to be edited with the left and right band select buttons
and adjust the value with the knob.
HH Enable
The
HH ENABLE button will allow Hot Hand
®
control for an individual
preset so it can be used on one preset and not on another.
Calibration
The
MWD Pro has a calibration feature which is only used in Hot Hand
mode. However, calibration is not required before use. The calibration
feature allows you to set the
MAXIMUM point of the DRIVE sweep for any
position of your hand. Depending on your playing style, you may nd it
useful to try some different calibration positions. The default and most
common use of calibration is to have your hand pointing straight up as
the maximum point of the
DRIVE sweep. Calibration can also be useful
if you are putting the sensor on a headband or other alternate locations.
Calibration mode can only be enabled when
HH ENABLE in ON. Calibra-
tion settings are saved per preset.
To perform a calibration:
1. Select a preset by pressing a footswitch.
2. Enable Hot Hand control by pressing the
HH ENABLE button.
3. Press the
CALIBRATE button to put the MWD Pro into Calibrate Mode.
4. Put the Hot Hand sensor into the desired calibration position.
5. Press the footswitch for the currently selected preset.
6. The Calibrate
LED will blink to when the calibration is complete.
If you have trouble with calibration and need to get back to the default
setting, point the front of the sensor (the H logo) straight up towards the
ceiling and run the calibration procedure again.
125 250 500 1K 2K
(NG) (HG) (HS) (HA) (HR) (CR)
4K 8K
+12
-12
0
< >
+12
-12
0
HH ENABLE
CALIBRATE
BACKPAGE
MODE
- Continued
Vue de la page 10
1 2 ... 6 7 8 9 10 11 12 13

Commentaires sur ces manuels

Pas de commentaire